Unlock Real-time Data Monitoring With Remote I/O

Today’s industries rely on real-time data and smart devices to boost efficiency. Moxa’s remote I/Os exemplify this shift, providing proactive intelligence, simple deployment and setup, and industrial-grade reliability to ensure stable connectivity and real-time data access for smarter operations. Watch the short video to see how our remote I/O field partner works alongside you to simplify monitoring and enable smarter, real-time decisions—anytime, anywhere.



Why Moxa

1. Proactive

Our remote I/Os feature event-driven push and Click&Go Plus Logic to move beyond polling, reducing host reliance and streamlining IT/OT integration.

Event-driven push technology

With push-type communication, remote I/Os send data only when changes occur, significantly reducing unnecessary network traffic. Unlike pull-based systems that constantly poll devices, this method enables faster system responses and lowers overall bandwidth usage. More importantly, by offloading routine data handling from the host system, push communication helps free up computing resources, allowing the upper system to focus on higher-level applications and real-time analysis.

Supported Models:
ioLogik E1200 Series, ioLogik 2500 Series

Intuitive Click&Go Plus logic

Moxa’s Click&Go Plus Logic enables smart, front-end control logic by executing event-based actions directly on the device—eliminating the need for constant communication with a host. You can configure logic rules using an intuitive graphical interface with simple if-then-else conditions. By processing logic at the edge, devices react instantly to field events and reduce host dependency to boost overall efficiency.

Supported Models:
ioLogik 2500 Series

2. Easy to Use

Effortless setup with front wiring and daisy-chained Ethernet simplifies installation and lowers effort, cost, and complexity.

 

Front-wiring design

The front-facing wiring design makes installation easier and more efficient by allowing direct access to terminals. This design not only simplifies wiring but also helps save over 50% of the required DIN-rail installation space, making it ideal for compact control panels.

Supported Models:
ioLogik E1200 Series, ioLogik R1200 Series, ioLogik 2500 Series, ioThinx 4510 Series

Dual LAN ports for daisy-chain networks

With two built-in LAN ports, devices can be directly connected in a daisy-chain configuration without needing an external switch. This simplifies network architecture, reduces wiring complexity, and lowers both installation time and costs.

Supported Models:
ioLogik E1200 Series, ioThinx 4510 Series

User-defined Modbus address

The ability to modify Modbus addresses allows the device to fit easily into existing systems without requiring major changes to configurations. This flexibility reduces implementation effort, minimizes downtime, and ensures smoother integration with legacy equipment.

Supported Models:
ioLogik E1200 Series, ioLogik 2500 Series, ioThinx 4510 Series

 

3. Reliable

Designed for harsh environments, our remote I/Os ensure reliable performance from manufacturing to outdoor deployments.

 

Industry-leading 5-year warranty

They are designed for long-term reliability, offering the longest warranty in the industry for peace of mind.

Wide operating temperature

Devices are engineered to withstand extreme heat and cold, ensuring stable performance in harsh environments.

High-stability RS-485

They provide 137% better noise immunity for robust and secure communication (ioLogik R1200 available only).


Choose the Right Remote I/O for Your Needs

ioLogik E1200 Series

Ethernet remote I/O

ioLogik R1200 Series

RS-485 remote I/O

ioLogik 2500 Series

Smart remote I/O

ioThinx 4510 Series

Modular remote I/O

  • Effortless installation
    Compact front-wiring design streamlines setup
  • Smart networking
    Built-in 2-port Ethernet switch for daisy-chain connectivity
  • Seamless IT integration
    Supports Modbus TCP, RESTful API, and SNMP
  • Proactive data reporting
    Real-time active communication via MX-AOPC UA Suites
  • Fast and easy deployment
    Compact front-wiring design for simplified installation
  • Superior stability
    137% wider common mode voltage enhances RS-485 reliability
  • Reliable connectivity
    Dual RS-485 or repeater mode for flexible wiring and data flow continuity
  • Hassle-free maintenance
    Configure communication parameters and upgrade firmware via USB or RS-485
  • Edge Intelligence
    Built-in Click&Go Plus logic enables local decision making
  • Highly scalable
    Expandable with up to 8 additional ioLogik E1200 units
  • Flexible connectivity
    4-port Ethernet switch and dual serial ports for seamless integration
  • Reliable data continuity
    Auto lost data recovery via MX-AOPC UA Suites
  • Quick installation
    Tool-free setup and auto reconfiguration reduce downtime
  • Flexible expansion
    Supports up to 32 modules for scalable applications
  • Multiple connectivity options
    2-port Ethernet switch and 3-in-1 serial port for various industrial setups
  • IT-ready design
    Supports Modbus TCP, RESTful API, MQTT, and SNMPv3 for modern IIoT integration

Where Remote I/Os Make a Difference

1. Intelligent Transportation

From bridges to airports, Moxa’s remote I/Os ensure reliable control of outdoor systems like lighting, roadside cabinets, and field devices—using a compact, rugged design built for harsh environments.

Bridge Lighting Control System

Long-distance bridge lighting systems require energy-efficient, cost-effective, and scalable control mechanisms. Traditional star networks are insufficient for large-scale infrastructure, necessitating a robust Ethernet I/O solution for long-distance connectivity.

System Requirements

  • Must reduce wiring costs across long bridge spans
  • Integrates easily with embedded control systems
  • Operates reliably in harsh outdoor conditions

Why Moxa

  • Daisy-chain Ethernet topology reduces cabling and switch costs
  • SNMP and Modbus support simplify integration with edge computing
  • Rugged, compact I/O ideal for roadside or bridge cabinet installation

Airport Facility Monitoring

Airport facilities must adhere to stringent cybersecurity and data integrity regulations. Remote I/O solutions must ensure encrypted data transmissions, real-time alerts, and flexible I/O support to meet diverse monitoring needs in outdoor terminals and remote control cabinets.

System Requirements

  • Must comply with national encryption policies
  • Secure bidirectional communication (SNMPv3)
  • Modular I/O options for diverse sensor types

Why Moxa

  • Supports SNMPv3 for encrypted communication and SNMPv3 Trap for proactive data updates
  • Modular design adapts to different facility monitoring scenarios
  • Reliable in harsh environments from -40 to 75°C

2. Data Center

Whether monitoring temperature, integrating power meters, or upgrading legacy systems, Moxa remote I/Os offer flexible, space-saving solutions that connect smoothly to IT systems via Modbus or SNMP.

High-Density Environmental Monitoring

Large-scale data centers demand highly scalable monitoring systems to maintain operational stability. High-density installations are possible with distributed I/O deployed via Ethernet daisy-chain, avoiding complex rewiring and infrastructure upgrades.

System Requirements

  • IT-based management system to monitor the data center environment
  • Supports daisy-chain network for distributed installation space

Why Moxa

  • SNMP support can be easily integrated into a network management system
  • Built-in 2-port switch for daisy-chain network topology
  • Compact size to fit into any installation space

Cost-Effective Serial Monitoring

Data centers aren’t always newly built. Many cost-conscious areas depend on their existing RS-485 infrastructure for power and environmental monitoring. These deployments require a simple, compact, and low-maintenance solution that fits into limited spaces while collecting critical signals such as ATS, UPS, lighting, fans, and HVAC data. A serial-based I/O system offers a cost-effective path to digitizing legacy systems without a complete network replacement.

System Requirements

  • Using existing serial network because of cost concerns and low IP management issues
  • Multiple status, e.g., ATS, UPS, light, fan, temperature, humidity, etc., to collect
  • Limited installation space

Why Moxa

  • Compact size with front-wiring design to minimize the installation space needed
  • Industrial leading 5-year warranty

Power Meter and Sensor Integration in One System

Meeting energy transparency and efficiency demands requires data centers to integrate power meter and environmental sensor data onto a single monitoring platform. Timely data delivery and system simplification are achieved by integrating analog signals and serial Modbus meters through a secure IT-friendly protocol such as SNMPv3.

System Requirements

  • Centralized monitoring for both environmental and energy data
  • Integration with serial power meters (Modbus RTU)
  • Simplified installation across distributed server rooms

Why Moxa

  • Supports SNMPv3 Trap for secure, proactive data updates
  • Built-in Modbus RTU client to collect serial power, making I/O and meters data collection via Ethernet possible
  • Daisy-chain topology and front-wiring simplify deployment in tight spaces

3. Manufacturing

From factory emissions to machine status signals, Moxa remote I/Os help digitalize operations with easy installation, diverse I/O support, and seamless integration to MES or SCADA platforms.

Continuous Emission Monitoring System

Environmental regulations now require factories to submit accurate emission data every 15 minutes—or risk heavy penalties. In facilities with distributed sources operating in harsh conditions, robust data transmission and recovery systems are essential to prevent data loss and meet regulatory requirements.

System Requirements

  • Must update emission data to DAHS every 15 minutes
  • Zero data loss allowed—non-compliance leads to fines
  • Must operate reliably in outdoor, industrial conditions

Why Moxa

  • ioLogik 2500 with MX-AOPC UA ensures automatic data backup and recovery
  • Active data delivery to DAHS ensures timely compliance
  • Rugged, wide-temperature design ready for harsh field environments
  • More cost-effective compared to traditional SCADA systems

Machine Status Monitoring

To improve OEE and lay the groundwork for smart manufacturing, factories need visibility of machine availability. Capturing tri-color tower light signals from legacy machines and integrating them into MES systems is a critical first step in this transformation.

System Requirements

  • Capturing machine status from legacy equipment lacking Ethernet
  • Must fit into tight spaces near tri-color light towers
  • Integration with existing MES

Why Moxa

  • Compact I/O design fits into tight machine enclosures
  • ioLogik E1200 captures light tower status and pushes updates via MX-AOPC
  • MX-AOPC supports OPC UA for seamless MES integration

Selection Guide

Remote I/Os

ioLogik E1200 Series

ioLogik R1200 Series

ioLogik 2500 Series

ioThinx 4510 Series

I/O DI, DO, Relay, AI, AO, RTD, TC DI, DO, Relay, AI, AO DI, DO, AI
(Relay, AO, RTD, TC expandable
by ioLogik E1200 series)
DI, DO, Relay, AI, AO, RTD,
TC expandable by 45MR Series
Front-end logic - - Click&Go Plus -
Ethernet port 2 - 4 2
Serial - 2 x RS-485 2 x RS-232/422/485 1 x RS-232/422 or 2 x RS-485
Northbound protocol Modbus TCP server (slave)
EtherNet/IP adapter
SNMPv1/v2c
RESTful API
Modbus TCP server (slave) Modbus TCP server (slave)
SNMPv1/v2c/v3
RESTful API
Modbus TCP server (slave)
SNMPv1/v2c/v3
RESTful API via TLS
Active protocol Moxa AOPC (Active tag)
SNMPv1 Trap
- Moxa AOPC (Active tag)
SNMPv1/v2c Trap
CGI command
MQTT via TLS
SNMPv1/v2c/v3 Trap
SNMPv2c/v3 Inform
Southbound protocol - - Modbus TCP client (master)
Modbus RTU client (master)
Modbus RTU client
Operating Temp. range Standard models:
-10 to 60°C (14 to 140°F)
Wide temp. models:
-40 to 75°C (-40 to 167°F)
Standard models:
-10 to 75°C (14 to 167°F)
Wide temp. models:
-40 to 85°C (-40 to 185°F)
Standard models:
-10 to 60°C (14 to 140°F)
Wide temp. models:
-40 to 75°C (-40 to 167°F)
Standard models:
-20 to 60°C (-4 to 140°F)
Wide temp. models:
-40 to 75°C (-40 to 167°F)
Standards and Certifications CID2, ATEX Zone 2,
CE, FCC, UL
CE, FCC, UL CID2, ATEX Zone 2,
CE, FCC, UL
CID2, ATEX Zone 2,
CE, FCC, UL
  •  

REQUEST INFORMATION

sales@excelnex.com