| NPort
6110 |
|
| Easy-to-use
Ethernet to RS-232/485/422 Modbus Gateway |
| |
|
|
Seamless
Integration for Ethernet and Serial Modbus
Device |
|
| |
Modbus is one of the most popular automation
protocols in the world. Modbus protocol supports
traditional RS-232/422/485 devices and newly
developed Ethernet devices. Many industrial
devices, such as PLCs, DCSs, HMIs, instruments,
and meters, use Modbus as their communication
standard. However, the Modbus protocol running
over serial and Ethernet are so different
that a communication gateway is needed as
a bridge for integration.
NPort 6110 supports one Ethernet and one software
selectable RS-232/422/485 port that can connect
with all kinds of Modbus devices. By translating
Modbus/TCP (Ethernet) and Modbus /ASCII/RTU
(Serial) protocols, a PLC with Ethernet can
use the RS-232/422/485 interface to seamlessly
communicate with instruments.
|
|
| 
Larger Picture
|
| |
Powerful
Operation Modes for Versatile Modbus Applications |
| |
For Modbus protocol conversions, it is necessary
to define a Master and Slave device, but unlike
other Modbus Gateways, NPort 6110 allows users
to configure Master/Slave for both the Ethernet
and serial sides. Extra address mapping and
exception parameters are supplied to ensure
that most situations can be handled.
|
|
Windows
Utility For Easy Setup and Traffic Monitoring |
| |
NPort 6110 is powerful yet very easy to use.
An intuitive Windows utility automatically
searches for all available NPort 6110 units
on the LAN. Traffic monitoring within the
utility helps you troubleshoot any Modbus
communication problem, such as connection
status check, or address translation error
check. |
Typical Applications
Serial
Master device talks to serial slave devices
over the Internet |
| |
Let traditional Modbus serial devices
talk over the Internet
Many traditional serial Modbus devices can
talk over RS-485, but the RS-485 network limits
the maximum number of Modbus devices to 32,
within 1.2 km. By using Modbus Gateway, you
can link all Serial Modbus devices over an
Ethernet network. Up to 8 Modbus Gateways
can be installed in the same control network,
extending the coverage of a single Modbus
network as far as a TCP/IP network can reach. |
| |
|
Ethernet
master devices talk to multiple serial slave
devices |
| |
Connect all Modbus devices over the Ethernet
network
Most host computers and newly developed PLCs
support the Ethernet interface and run Modbus/TCP.
NPort 6110 Modbus Gateway is needed to link
discrete Serial Modbus Devices for data collection
and control. Each NPort 6110 supports Modbus/TCP
over Ethernet, which allows up to 7 connections.
The software configurable serial interface
supports either RS-232 or RS-422/485. In RS-232/422
modes, NPort 6110 can connect to 1 serial
device. One NPort 6110 supports up to 31 serial
devices under RS-485 mode, which is the most
popular application for the factory floor.
|
| |
|
Serial
master devices talk to multiple Ethernet slave
devices |
| |
Link the Serial Master device with Ethernet
Slave devices
Many HMI (Human Machine Interface) systems
use a serial interface and are required to
access a discrete DCS. These days however,
more and more DCSs support Ethernet and run
under Modbus/TCP slave mode. In this case,
NPort 6110 Modbus Gateway is the ideal solution
to link the HMI to distributed DCSs over an
Ethernet network. Up to 4 Modbus/TCP slave
devices are supported for each NPort 6110. |
| |
|
Easy-to-use
Windows utility |
| |
Configure Modbus Gateway Anywhere on the
LAN
Once NPort 6110 is connected to the Ethernet,
any Windows host computer running Modbus Gateway
Configurator can automatically search for
all installed Modbus Gateways, and then proceed
with configuration. DHCP (Automatic IP settings)
and Manual IP settings are both supported.
Such user-friendly features make NPort 6110
one of the most easy-to-use Modbus Gateways
in the world.
Online Traffic Monitoring and Error Log
Display
Modbus communication troubleshooting is both
fast and easy. NPort 6110's utility lets you
monitor the online configuration and connection
status from anywhere on the network without
interfering with operation. Meanwhile, the
system log can be stored as an installation
or service record.
|
| |
|
Comprehensive
and Powerful Modbus parameter settings |
| |
In addition to working with most Modbus devices,
NPort 6110 provides both basic and advanced
communication parameters. For example, in
addition to general configurations, Remote
Modbus/TCP device ID, Initial Delay Time Adjustment,
and Character/Message Timeouts are adjustable
right in the Windows utility. Unlike text-based
configuration from other vendors, NPort 6110's
comprehensive utility eases installation and
saves training cost for engineers. |
| |
|
Features |
| |
- Modbus serial and Ethernet device integration
- Supports Modbus/TCP Master device to Modbus/ASCII/RTU
slave devices (up to 31)
- Supports Modbus/ASCII/RTU master device
to Modbus/TCP slave devices (up to 4)
- Easy-to-use Windows utility for configuration
over Ethernet
- 10/100M fast Ethernet with automatic IP
setting (DHCP)
- One software selectable RS-232/485/422
interface
- High speed serial up to 230.4 Kbps
|
Specifications
LAN
| Ethernet |
10/100
Mbps, RJ45 |
| Protection |
Built-in
1.5 KV magnetic isolation |
Serial
| Interface |
RS-232/422/485
x 1, DB9 (M), software selectable |
| RS-232
signals |
TxD,
RxD, RTS, CTS, DTR, DSR, DCD, GND |
| RS-422 signals |
Tx+,
Tx-, Rx+, Rx-, GND |
| RS-485
2-wire Signals |
Data+,
Data-, GND |
| Serial
Line Protection |
15 KV
ESD for all signals |
| RS-485 Data Direction |
Patented
Automatic Data Direction Control
(ADDC™) |
Serial Communication Parameters
| Parity |
None,
Even, Odd, Space, Mark |
| Data
bits |
7, 8 |
| Stop
bits |
1, 2 |
| Flow
control |
RTS/CTS,
XON/XOFF |
| Speed |
1200
bps to 230.4 Kbps |
Software Features
| Internet Protocols |
DHCP,
BootP, TCP, UDP, IP, ICMP, ARP |
| Modbus Protocols |
Modbus/TCP,
Modbus/ASCII,
Modbus/RTU, Master/Slave modes supported |
| Utilities |
Modbus
Gateway Configurator for
Windows 95/98/ME/NT/2000/XP |
| Configuration |
Windows
utility via Ethernet |
Power Requirements
| Power
Input |
9
to 30 VDC |
| Power
Consumption |
300
mA at 12V (max.) |
Mechanical Specifications
| Material |
Aluminum
sheet metal (1 mm) |
| Gross
Weight |
0.5 kg
(1.1 lb) |
Environmental
| Operating
Temperature |
0
to 55°C (32 to 131°F), 5 to 95% RH |
| Storage
Temperature |
-20
to 85°C (-4 to 185°F), 95% RH |
Regulatory Approvals
| EMC |
FCC
Class B, CE Class B |
| Safety |
CUL,
TÜV |
| Pin Assignment
DB9 Male
 |
| Pin |
RS-232 |
RS-422 |
RS-485(2W) |
|
1 |
DCD |
Tx-(A) |
Data-(A) |
| 2 |
Rx |
Tx+(B) |
Data+(B) |
| 3 |
Tx |
Rx+(B) |
- |
| 4 |
DTR |
Rx-(A) |
- |
| 5 |
GND |
GND |
GND |
| 6 |
DSR |
RTS-(A) |
- |
| 7 |
RTS |
RTS+(A) |
- |
| 8 |
CTS
|
CTS+(B) |
- |
| 9 |
----
|
CTS-(A) |
- |
|
Dimensions
|
Ordering Information
| NPort 6110 |
NPort
6110 Modbus/TCP to Serial Gateway with 100-240
VAC power adapter (US, Euro plugs included,
12V, 400 mA) |
Optional Accessories
| DK-35A |
DIN-Rail
Mounting Kit (35 mm) |
|
|
|
|
|