| Industrial
Media Converter IMC-101 |
|
| Industrial 10/100BaseT(X)
to 100BaseFX Media Converter |
Link Fault Pass-Through |
| |
IMC-101's "Link Fault Pass-Through" feature
overcomes a problem encountered when using
traditional media converters. The problem
is this. When one side of the link fails,
the other side continues transmitting packets,
and then waits for a response that never arrives
from the disconnected side.
What IMC-101 does is force the link to shut
down as soon as it notices that the other
link has failed,giving the application software
a chance to react to the situation. |
|
Redundant Power Inputs |
| |
IMC-101 provides two power inputs that can
be connected simultaneously to live DC power
sources. If one power input fails, the other
source acts as a backup, and automatically
satisfies IMC-101's power needs. |
Relay Ouput Alarm by Port Break,
Power Failure |
| |
IMC-101 provides relay contact outputs to
warn technicians on the shop floor when the
power fails or a port link is disconnected,
so they can respond quickly with appropriate
emergency operation procedures. |
Features |
| |
- Supports 10/100BaseT(X) auto-negotiation
and auto-MDI/MDIX
- Multi mode, single mode with SC or ST
fiber connector available
- Supports Link Fault Pass-Through
- Relay output alarm when a port breaks
or the power fails
- Redundant 12 to 48 VDC power inputs, DIN-Rail
or panel mountable
|
Specifications
Interface
| RJ45
ports |
10/100BaseT(X)
|
| Fiber
ports |
100BaseFX
(SC, ST connectors available) |
| LED
Indicators |
Power,
Fault, 10/100, Full/Half Duplex, Collision |
| Dip
Switch |
100BaseFX
Full/Half duplex selection, Port break alarm
mask |
| Alarm
Contact: |
One relay
output with current carrying capacity of 1A
@ 24 VDC |
Technology
| Standards |
IEEE802.3,
802.3u, Link Fault Pass-Through |
Optical Fiber
| Distance |
Single
mode fiber for 15 km,
Multi mode fiber for 2 km |
| Wavelength |
1310
nm |
| Min.TX
Output |
-20 dBm
(IMC101-M), -15 dBm (IMC101-S) |
| Max.TX
Output |
-14 dBm
(IMC-101-M), -6 dBm (IMC-101-S) |
| Sensitivity |
-36 to
-32 dBm (IMC101-M),
-34 to -32 dBm (IMC101-S) |
Power
| Input
Voltage |
12 to
48 VDC; Redundant inputs |
Input
Current
(@24V) |
0.2A |
| Connection |
Removable
Terminal Block |
| Overload
Current Protection |
1.1A |
| Reverse
Polarity Protection |
Present |
Mechanical
| Casing |
IP30
protection, aluminum case |
| Weight |
0.63
kg |
Dimensions
(W x H x D) |
53.6
x 135 x 105 mm |
| Installation |
DIN-Rail,
Wall Mounting |
Environment
| Operating
Temperature |
0 to
60°C (32 to 140°F) |
| Storage
Temperature |
-40 to
85°C (-40 to 185°F) |
| Ambient
Relative Humidity |
5 to
90% (non-condensing) |
Regulatory Approvals
| UL/CUL |
UL60950 |
| TÜV |
EN60950 |
| FCC |
Part
15 class A |
| EMI |
EN55022 |
| EMS |
EN61000-4-2
(ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3 |
| Shock |
IEC 60068-2-27 |
| Free
fall |
IEC 60068-2-32 |
| Vibration
|
IEC 60068-2-6 |
| WARRANTY |
Five
years |
Ordering Information
| IMC-101-M-SC |
- Industrial 10/100BaseT(X) to 100BaseFX
media converter, multi mode, SC fiber connector
|
| IMC-101-M-ST |
- Industrial 10/100BaseT(X )to 100BaseFX
media converter, multi mode, ST fiber connector
|
| IMC-101-S-SC |
- Industrial 10/100BaseT(X) to 100BaseFX
media converter, single mode, SC fiber connector
|
| All
items include User's Manual |
Optional Accessory
|
|
|
|
|