DR-4524
|
|
| 45W DIN-Rail 24 VDC
Power Supply |
Overview |
| |
The DR series of power supplies provides
a reliable DC power source for any industrial
control system. Combining rugged, compact
enclosures, incorporating all international
standards and approvals, and offering short
circuit, over load, over voltage, and over
temperature protection, the DR series makes
your power supply choice a simple one.These
high quality power supplies have passed a
100% full load burn-in test, and are UL/CUL
listed, TUV/CB certified, and CE marked. Models
are available with output ratings from 45W
to 120W, with 24 VDC output. Customers can
choose from a full range of input voltages
(85 to 264 VAC and 120 to 370 VDC compatible)
making the DR series unbeatable. |
|
Features |
| |
- Universal AC input (85 to 264 VAC)
- DC compatible input (120 to 370 VDC)
- CE marked and UL508 listed
- Certified to TUV EN60950
- Simple snap-on for TS35/7.5 or TS35/15
DIN-Rail
- 100% full load burn-in test
- Free air cooling convection
- Built in EMI filter and low ripple noise
- 105°C output capacitor
- Short circuit, overload, over voltage
protected
|
Benefits |
| |
- Economical and reliable DC power source
for industrial devices
- Design for use in harsh industrial environment
|
Applications |
| |
- Factory automation
- Transportation automation
- Utility automation
- Building automation
|
Specifications
Input
| Input
voltage |
85-264VAC
or 120-370VDC |
| Input
frequency |
47-63
Hz |
| Input
current |
1.5A/115VAC
or 0.75A/230VAC |
Output
| DC
output power |
48 W |
| Output
voltage |
24 VDC |
| Output
V. tolerance |
±1% |
| Output
rated current |
2A |
| Output
current range |
0-2A |
| Ripple
and noise |
480mVp-p |
| Line
regulation |
±1% |
| Load
regulation |
±1% |
| Efficiency |
80% |
| DC
voltage adjust |
±10% |
| Setup,
rise and hold up time |
800 ms,
60 ms and 50 ms / 230V |
Regulatory Approval
| Safety
standards |
TUV EN60950,
UL508 Approved |
| EMC
standards |
CISPR22
(EN55022) CLASS B,
EN61000-4-2,3,4,5,6,8,11; ENV50204,
EN61000-3-2,-3, EN50082-2 |
Operating protection
| Inrush
current |
Cold
start at 30A/115V or 60A/230V |
| Leakage
current |
<
1 mA / 240 VAC |
| Withstand voltage |
Between
input and output 3 KVAC
Between input and frame ground: 1.5 KVAC
Between output to frame ground: 0.5 KVAC |
| Isolation
resistance |
Between
input and output/input and frame ground/ output
and frame ground: 500 VDC/100 Ohms |
| Overload
protection |
105-150%
Type: Constant Current Limiting. Reset: Auto
Recovery |
| Over
voltage protection |
115-135
VDC |
| Over
temperature protection |
135°C,
typically power shutdown |
Mechanical
Dimensions
(W x H x D) |
78 x
93 x 67 mm |
| Weight
(kg) |
0.4 |
Environment
| Working
temp. and humidity |
-10°C
to 50°C
,20 to 90% RH |
| Temp.
coefficient |
5 to
90% (non-condensing) |
| Storage
temp. and humidity |
-20°C
to 85°C, 10 to 95% RH |
| Vibration |
10-500
Hz, 2G 10 min./1cycle, Period for 60 min. Each
Axis |
| 3-year
warranty |
Solid
3-year warranty backed by experienced and friendly
technical support personnel |
Ordering Information
| DR-4524 |
- 45W/2A DIN-Rail 24 VDC Power Supply with
universal 85 to 264 VAC input
|
|
|
|
|
|